Services Available | |
---|---|
Repair | Yes |
Calibration | No |
Free Support | Yes |
El datalogger CR200X proveé una operacion en solitario para operaciones en ambientes hostiles y remotos. Lee y guarda los datos de uno o dos sensores quie luego puede transmitir por diferentes vias usando nuestros dispositivos de comunicación. PErmite una configuracion simple o programaciones mas avanzadas y complejas. Multiples CR200X se pueden usar en red.
Read MoreThe CR200X has several input channels for measuring a variety of sensors. Gas discharge tubes provide rugged electrostatic discharge protection for the inputs.
The CR200X does not make differential measurements and is not compatible with SDM devices, multiplexers, or thermocouples (refer to the Compatibility information for compatible sensors, peripherals, and software). Recalibration services are not offered for the CR200X datalogger.
-NOTE- | Note: Additional specifications are listed in the CR200X-Series Specifications Sheet. |
Maximum Scan Rate | 1 Hz |
Analog Channels |
|
Pulse Count Channels | 2 |
Switched Excitation Channels | 2 voltage |
Digital Ports |
|
Communication Ports | 1 RS-232 |
Switched Battery Port | 1 |
Input Voltage Range | 0 to 2500 mV |
Analog Voltage Accuracy | ±(0.25% of reading + (1.2 mV)x(offset)) at -40° to +50°C |
Analog Voltage Resolution | 0.6 mV |
A/D Bits | 12 |
Operating Temperature | -40° to +50°C |
Power Requirements | 7 to 16 Vdc |
Typical Current Drain |
|
Protocols Supported | PakBus (leaf node only), SDI-12 |
CE Compliance Standards to which Conformity Is Declared | IEC61326:2002 |
Warranty | 3 years |
Dimensions | 14.0 x 7.6 x 4.8 cm (5.5 x 3.0 x 1.9 in.) |
Weight | 242 g (8.5 oz) |
Memory |
|
Final Storage | 512 kB of flash memory for approximately 125,000 data points |
Operating System | 106 kB of flash memory |
Intermediate Storage | 8 kB of SRAM for communication buffers, calculations, variables, etc. |
Please note: The following shows notable compatibility information. It is not a comprehensive list of all compatible products.
Product | Compatible | Note |
---|---|---|
014A-L | ||
03002-L | ||
03101-L | ||
034B-L | ||
05103-45-L (retired) | ||
05103-L | ||
05106-L (retired) | ||
05305-L | ||
083E-L (retired) | ||
092-L (retired) | ||
107 | ||
108 | ||
109 | ||
109SS-L | ||
110PV-L (retired) | ||
237-L (retired) | ||
255-100 | ||
27106T-L | ||
43347-L | ||
52202-L | ||
A100LK-L | ||
CMP11-L (retired) | ||
CMP21-L | ||
CMP3-L | ||
CMP6-L (retired) | ||
CS100 | ||
CS106 | ||
CS215-L (retired) | ||
CS300-L (retired) | ||
CS410-L (retired) | ||
CS451 | ||
CS456 | ||
CS460-L (retired) | ||
CS470 (retired) | ||
CS471 (retired) | ||
CS475A-L | ||
CS475-L (retired) | ||
CS476-L (retired) | ||
CS477-L (retired) | ||
CS511-L | ||
CS526-L (retired) | ||
CS547A-L | ||
CS616 | ||
CS625 (retired) | ||
CS650 | ||
CS655 | ||
CS700-L | ||
CSAT3 (retired) | ||
CSIM11-L | ||
CSIM11-ORP-L | ||
ENVIROSCAN (retired) | ||
HC2S3-L (retired) | ||
HMP155A-L | ||
HMP60-L | ||
LI190SB-L (retired) | ||
LI200X-L (retired) | ||
LWS-L | ||
OBS-3+ (retired) | ||
OBS300 (retired) | ||
OBS500 (retired) | ||
P2546A-L | ||
SEN12512 (retired) | ||
SR50A-L (retired) | ||
TB4-L | ||
TB4MM-L | ||
TE525-L | ||
TE525MM-L | ||
TE525WS-L | ||
WINDSONIC1-L | ||
WINDSONIC4-L | ||
WXT520 (retired) |
Product | Compatible | Note |
---|---|---|
LoggerNet | Version 2.1 or higher | |
PC200W (retired) | ||
PC400 | Version 1.0 or higher | |
PCONNECT (retired) | Version 3.0 or higher | |
PCONNECTCE (retired) | Version 2.0 or higher | |
Short Cut | ||
VISUALWEATHER | Version 2 or higher |
The CR200X can communicate with a PC via direct connect, NL201 Network Link Interface, NL240 Wi-Fi Network Link, MD485 multidrop modem, and digital cellular modems. Data can be viewed on an iOS device, an Android device, CD295 DataView II Display, or a user-supplied PDA. To use an iOS or Android device, go to the Apple Store or Google Play and download our LoggerLink Mobile Apps free of charge. User-supplied PDAs require either PConnect or PConnectCE software.
The CR200X is not compatible with SDM devices and multiplexers.
The CR200X can measure a variety of sensors including SDI-12 sensors and 4 to 20 mA sensors. It cannot make differential measurements and is not compatible with the freezing-rain/ice, fuel moisture/temperature, geographic position, present weather, soil heat flux, soil matric water potential, and strain sensors listed on our price lists.
Applications with minimal power requirements can use the ENC200 enclosure to house the data logger and the pn 16869 sealed rechargeable battery. The ENC200 cannot house a barometer or a battery that is larger than the pn 16869. However, an ENC10/12 or ENC12/14 enclosure is adequate for most CR200X-based systems.
The CR200X uses an external power supply and has a built-in regulator. When connected to the on-board charging circuit, the sealed rechargeable battery should be 7 A h or smaller. Using larger batteries with the data logger's built-in charger may result in excessive PC board heating. This is especially a concern when the battery is deeply discharged or failing with a shorted cell. Campbell Scientific also recommends that solar panels be 10 W or less and wall chargers be 1 A or smaller.
Execution of this download installs the Operating System and Compiler on your computer for the following dataloggers:CR200X, CR206X, CR211X, CR216X and CR295X. It also updates the support files for the CRBasic Editor.
Note: Newer CR206X dataloggers (serial # ≥ 19122) and newer CR211X dataloggers (serial # ≥ 19143) have 250 mW radios that must use OS 3 or higher for their datalogger operating system.
Number of FAQs related to CR200X: 1
The CR200X-series and the retired CR200-series dataloggers are NOT compatible with SDMs or multiplexers. If more channels are needed or may be needed in the future, consider purchasing a CR800, CR850, or CR1000 instead.