Services Available | |
---|---|
Calibration | Yes |
The HC2S3, manufactured by Rotronic, is a rugged, accurate temperature and humidity probe that is ideal for long-term, unattended applications. The probe uses an advanced capacitive sensor to measure relative humidity. The probe includes a filter to protect the sensor from dust and particles, for superior performance and reliability.
Read MoreThe HC2S3 comes with a polyethylene filter that protects its sensor from fine dust and particles and minimizes water absorption and retention. Alternatively, a Teflon filter is available for marine environments. The response time is slower when using the Teflon filter.
Electronics Operating Limits | -40° to +100°C |
Storage Temperature Range | -50° to +100°C |
Current Consumption |
|
Supply Voltage | 5 to 24 Vdc |
Startup Time |
1.5 s (typical) The startup time is a Rotronics specification. For programming, Campbell Scientific recommends a 2 s delay at 60°C, a 3 s delay at 0°C, and a 4 s delay at -40°C. |
Maximum Startup Current | < 50 mA (for 2 μs) |
Analog Outputs |
|
Diameter | 15 mm (0.6 in.) |
Length |
|
Weight | 10 g (0.35 oz) |
Air Temperature |
|
Measurement Range |
-40° to +60°C (default) Air temperature measurement ranges from -50° to +100°C are possible; contact Campbell Scientific for more information. |
Output Signal Range | 0 to 1 V |
Long-Term Stability | < 0.1°C/year |
Sensor Time Constant - Standard PE Filter | ≤ 22 s (63% step change [1 m/s air flow at sensor]) |
Sensor Time Constant - Optional Teflon Filter | ≤ 30 s (Typical 4 s, 63% of a step change [1 m/s air flow at sensor]) |
Temperature Accuracy | Refer to graph in probe manual. |
Relative Humidity |
|
Measurement Range | 0 to 100% RH (non-condensing) |
Output Signal Range | 0 to 1 Vdc |
Long-Term Stability | < 1% RH per year |
Accuracy | ±0.8% RH with standard configuration settings (at 23°C) |
Sensor Time Constant - Standard PE Filter | ≤ 22 s (63% of a 35 to 80% RH step change [1 m/s air flow at sensor]) |
Sensor Time Constant - Optional Teflon Filter | ≤ 30 s (Typical 10 s, 63% of a 35 to 80% RH step change [1 m/s air flow at sensor]) |
RH Accuracy over Temperature | Refer to graph in probe manual. |
Please note: The following shows notable compatibility information. It is not a comprehensive list of all compatible products.
Product | Compatible | Note |
---|---|---|
21X (retired) | ||
CR10 (retired) | ||
CR1000 (retired) | ||
CR1000X | ||
CR10X (retired) | ||
CR200X (retired) | ||
CR206X (retired) | ||
CR211X (retired) | ||
CR216X (retired) | ||
CR23X (retired) | ||
CR295X (retired) | ||
CR3000 (retired) | ||
CR500 (retired) | ||
CR5000 (retired) | ||
CR510 (retired) | ||
CR800 (retired) | ||
CR850 (retired) | ||
CR9000 (retired) | ||
CR9000X (retired) |
The HC2S3 should be housed in a 41003-5 10-plate naturally-aspirated solar radiation shield. This radiation shield mounts to a tripod or tower mast, crossarm, or user-supplied pole.