The CR216X is a small, low-cost datalogger that includes an internal 2.4 GHz spread-spectrum radio for transmitting data to another CR216(X), an RF416 radio, or RF432 radios. The 2.4 GHz frequency can be used worldwide.
The CR216X provides stand-alone operation in harsh, remote environments. It reads input from one or two sensors, then transmits its data wirelessly via its internal radio. Multiple CR216Xs can be configured as a network, or units can be deployed individually.
Read MoreThe CR216X can be used in a wireless sensor network. Wireless sensor networks are appealing because they are often more economical than trenching, laying conduit, and pulling wire. When used as a wireless sensor, the CR216X measures the sensors attached to it, then transmits its data wirelessly via its spread-spectrum radio to a master datalogger. The master datalogger must use the PakBus communication protocol (e.g., CR800,CR850, CR1000, CR3000). For more information on how to configure a PakBus system, please read our PakBus Networking Guide.
The CR216X has several input channels for measuring a variety of sensors. Gas discharge tubes provide rugged electrostatic discharge protection for the inputs.
The CR216X does not make differential measurements and is not compatible with SDM devices, multiplexers, or thermocouples. (Refer to the Compatibility information on the web page for compatible sensors, peripherals, and software.) Recalibration services are not offered for the CR216X dataloggers.
-NOTE- | Note: Additional specifications are listed in the CR200X-Series Specifications Sheet. |
Internal Spread-Spectrum Radio Operating Frequency Range | 2.450 to 2.482 GHz |
Transmitter Power Output | 50 mW |
Maximum Scan Rate | 1 Hz |
Analog Channels |
|
Pulse Count Channels | 2 |
Switched Excitation Channels | 2 voltage |
Digital Ports |
|
Communication Ports | 1 RS-232 |
Switched Battery Port | 1 |
Input Voltage Range | 0 to 2500 mV |
Analog Voltage Accuracy | ±(0.25% of reading + (1.2 mV)x(offset)) at -40° to +50°C |
Analog Voltage Resolution | 0.6 mV |
A/D Bits | 12 |
Operating Temperature | -40° to +50°C |
Power Requirements | 7 to 16 Vdc |
Typical Current Drain |
|
Protocols Supported | PakBus (leaf node only), SDI-12 |
CE Compliance Standards to which Conformity Is Declared | IEC61326:2002 |
Warranty | 3 years |
Dimensions | 14.0 x 7.6 x 4.8 cm (5.5 x 3.0 x 1.9 in.) |
Weight | 271 g (9.5 oz) |
Memory |
|
Final Storage | 512 kB of flash memory for approximately 125,000 data points |
Operating System | 106 kB of flash memory |
Intermediate Storage | 8 kB of SRAM for communication buffers, calculations, variables, etc. |
Please note: The following shows notable compatibility information. It is not a comprehensive list of all compatible products.
Product | Compatible | Note |
---|---|---|
014A-L | ||
03002-L | ||
03101-L | ||
034B-L | ||
05103-45-L (retired) | ||
05103-L | ||
05106-L (retired) | ||
05305-L | ||
083E-L (retired) | ||
092-L (retired) | ||
107 | ||
108 | ||
109 | ||
109SS-L | ||
110PV-L (retired) | ||
237-L (retired) | ||
255-100 | ||
27106T-L | ||
43347-L | ||
52202-L | ||
A100LK-L | ||
CMP11-L (retired) | ||
CMP21-L | ||
CMP6-L (retired) | ||
CS100 | ||
CS106 | ||
CS215-L (retired) | ||
CS300-L (retired) | ||
CS410-L (retired) | ||
CS451 | ||
CS456 | ||
CS460-L (retired) | ||
CS470 (retired) | ||
CS471 (retired) | ||
CS475A-L | ||
CS475-L (retired) | ||
CS511-L | ||
CS526-L (retired) | ||
CS547A-L | ||
CS616 | ||
CS625 (retired) | ||
CS650 | ||
CS655 | ||
CS700-L | ||
CSAT3 (retired) | ||
CSIM11-L | ||
CSIM11-ORP-L | ||
ENVIROSCAN (retired) | ||
HC2S3-L (retired) | ||
HMP155A-L | ||
HMP60-L | ||
LI190SB-L (retired) | ||
LI200X-L (retired) | ||
LWS-L | ||
OBS-3+ (retired) | ||
OBS300 (retired) | ||
OBS500 (retired) | ||
P2546A-L | ||
SEN12512 (retired) | ||
SR50A-L (retired) | ||
TB4-L | ||
TB4MM-L | ||
TE525-L | ||
TE525MM-L | ||
TE525WS-L | ||
WINDSONIC1-L | ||
WINDSONIC4-L | ||
WXT520 (retired) |
Product | Compatible | Note |
---|---|---|
LoggerNet | Version 2.1 or higher | |
PC200W (retired) | ||
PC400 | Version 1.0 or higher | |
PCONNECT (retired) | ||
PCONNECTCE (retired) | Version 2.0 or higher | |
Short Cut | ||
VISUALWEATHER | Version 2 or higher |
The CR216X can communicate with a PC via direct connect, NL201 Network Link Interface, NL240 Wi-Fi Network Link, MD485 multidrop modem, and digital cellular modems. Data can be viewed on an iOS device, an Android device, CD295 DataView II Display, or a user-supplied PDA. To use an iOS or Android device, go to the Apple Store or Google Play and download our LoggerLink Mobile Apps free of charge. User-supplied PDAs require either PConnect or PConnectCE software.
The CR216X's internal spread spectrum radio can transmit data to other CR216(X) loggers, RF416 radios, or RF430 radios. Certain CR216X settings must match the radio's settings for communications between the data logger and radio to be successful. The factory default settings of these devices might not match; therefore, they may need to be reconfigured before communications can take place.
If the CR216X is in the transparent mode, it can communicate with the retired CR215 loggers or RF415 radios.
Campbell Scientific’s SDM devices and multiplexers are not supported.
The CR216X can measure a variety of sensors including SDI-12 sensors and 4 to 20 mA sensors. It cannot make differential measurements and is not compatible with the freezing-rain/ice, fuel moisture/temperature, geographic position, present weather, soil heat flux, soil matric water potential, and strain sensors listed on our price lists.
Applications with minimal power requirements can use the ENC200 enclosure to house the data logger and the #16869 sealed rechargeable battery. The ENC200 cannot house a barometer or a battery that is larger than the #16869. However, an ENC10/12 or ENC12/14 enclosure is adequate for most CR216X-based systems.
The CR216X uses an external power supply and has a built-in regulator. When connected to the on-board charging circuit, the sealed rechargeable battery should be 7 A h or smaller. Using larger batteries with the data logger's built-in charger may result in excessive PC board heating. This is especially a concern when the battery is deeply discharged or failing with a shorted cell. Campbell Scientific also recommends that solar panels be 10 W or less and wall chargers be 1 A or smaller.
Execution of this download installs the Operating System and Compiler on your computer for the following dataloggers:CR200X, CR206X, CR211X, CR216X and CR295X. It also updates the support files for the CRBasic Editor.
Note: Newer CR206X dataloggers (serial # ≥ 19122) and newer CR211X dataloggers (serial # ≥ 19143) have 250 mW radios that must use OS 3 or higher for their datalogger operating system.
Number of FAQs related to CR216X: 1
The CR200X-series and the retired CR200-series dataloggers are NOT compatible with SDMs or multiplexers. If more channels are needed or may be needed in the future, consider purchasing a CR800, CR850, or CR1000 instead.