CS106 Barometer (500 to 1100 hPa)
Wider Pressure Range
Resides inside weatherproof enclosure
weather aplicaciones soportadas water aplicaciones soportadas energy aplicaciones soportadas gas flux and turbulence aplicaciones soportadas infrastructure aplicaciones soportadas soil aplicaciones soportadas

Overview

El CS106 mide presion barometrica de forma precisa y desatendida en el rango de 500 a 1100 milibares (por debajo del nivel del mar -como en una mina- y hasta 5485 msnm -18000 pies). Incluye un switch de 12 voltios, con un puerto de control deld atalogger se logra reducir el consumo al apagar y encender el sensor solo cuando sea necesario.

Este sensor se instala dentro de la caja hermetica que lo protege del medio ambiente y lo mantiene seco.

El barometro CS106 Vaisala PTB110 reemplazo  al barometro CS105 Vaisala PTB101B.

Read More

Benefits and Features

  • Optimized to mount in Campbell Scientific enclosures
  • Integral switching circuit limits power consumption to measurement cycle
  • Three-year warranty

Images

Detailed Description

The CS106 uses Vaisala’s BAROCAP silicon capacitive sensor to measure barometric pressure. It is encased in a plastic shell (ABS/PC blend) fitted with an intake valve for pressure equilibration.

The CS106 outputs a linear signal of 0 to 2.5 Vdc, which allows the barometer to be directly connected to a Campbell Scientific datalogger. An internal switching circuit allows the datalogger to power the CS106 only during measurement, which reduces power consumption.

Specifications

-NOTE- 1 hPa = 1 mBar
Pressure Range 500 to 1100 hPa
Long-Term Stability ± 0.1 hPa per year
Settling Time 1 s to reach full accuracy after power-up
Response Time 500 ms to reach full accuracy after a pressure step
Output Voltage 0 to 2.5 Vdc
Supply Voltage 10 to 30 Vdc
Elevation ~609.6 m (2,000 ft) below sea level (as in a mine) to 4,572 m (15,000 ft) above sea level
Accuracy
  • Accuracy refers to the root sum squared (RSS) of end point non-linearity, hysteresis, repeatability, and calibration uncertainty.
  • ±0.3 hPa (@ +20°C)
  • ±0.6 hPa (@ 0° to 40°C)
  • ±1.0 hPa (@ -20° to +45°C)
  • ±1.5 hPa (@ -40° to +60°C)
Linearity ±0.25 hPa
Hysteresis ±0.03 hPa
Repeatability ±0.03 hPa
Calibration Uncertainty ±0.15 hPa
Current Consumption
  • < 4 mA (active)
  • < 1 µΑ (quiescent)
Temperature Range -40° to +60°C
Dimensions 6.8 x 9.7 x 2.8 cm (2.7 x 3.8 x 1.1 in.)
Cable Length 76.2 cm (30 in.)
Weight 90 g (3.2 oz)

Compatibility

Please note: The following shows notable compatibility information. It is not a comprehensive list of all compatible products.

Dataloggers

Product Compatible Note
CR1000 (retired)
CR300
CR3000 (retired)
CR310
CR350
CR6
CR800 (retired)
CR850 (retired)

Additional Compatibility Information

Data Logger Considerations

A 2.5-ft cable is supplied with the sensor for connection to the data logger. The cable connects to a control port, single-ended analog input terminal, 12 V power terminal, and ground terminal on the data logger.

Mounting

The CS106 is typically mounted next to the data logger inside an ENC12/14 or larger enclosure. The very small ENC100 is available for housing the CS106 separately, in its own enclosure.

Documents

Casos de estudio

Utah Energy Industry: Air Quality and Met Monitoring
The past few years have seen a scramble within the power industry to use more......read more
Argentina: SCADA System for Agricultural Regions
In a country as large as Argentina, monitoring growing conditions in different agricultural regions is......read more

Articles and Press Releases

Listed Under

Common Accessory for the following products:
Replacement Part for the following products: