El CS106 mide presion barometrica de forma precisa y desatendida en el rango de 500 a 1100 milibares (por debajo del nivel del mar -como en una mina- y hasta 5485 msnm -18000 pies). Incluye un switch de 12 voltios, con un puerto de control deld atalogger se logra reducir el consumo al apagar y encender el sensor solo cuando sea necesario.
Este sensor se instala dentro de la caja hermetica que lo protege del medio ambiente y lo mantiene seco.
El barometro CS106 Vaisala PTB110 reemplazo al barometro CS105 Vaisala PTB101B.
Read MoreThe CS106 uses Vaisala’s BAROCAP silicon capacitive sensor to measure barometric pressure. It is encased in a plastic shell (ABS/PC blend) fitted with an intake valve for pressure equilibration.
The CS106 outputs a linear signal of 0 to 2.5 Vdc, which allows the barometer to be directly connected to a Campbell Scientific datalogger. An internal switching circuit allows the datalogger to power the CS106 only during measurement, which reduces power consumption.
-NOTE- | 1 hPa = 1 mBar |
Pressure Range | 500 to 1100 hPa |
Long-Term Stability | ± 0.1 hPa per year |
Settling Time | 1 s to reach full accuracy after power-up |
Response Time | 500 ms to reach full accuracy after a pressure step |
Output Voltage | 0 to 2.5 Vdc |
Supply Voltage | 10 to 30 Vdc |
Elevation | ~609.6 m (2,000 ft) below sea level (as in a mine) to 4,572 m (15,000 ft) above sea level |
Accuracy |
|
Linearity | ±0.25 hPa |
Hysteresis | ±0.03 hPa |
Repeatability | ±0.03 hPa |
Calibration Uncertainty | ±0.15 hPa |
Current Consumption |
|
Temperature Range | -40° to +60°C |
Dimensions | 6.8 x 9.7 x 2.8 cm (2.7 x 3.8 x 1.1 in.) |
Cable Length | 76.2 cm (30 in.) |
Weight | 90 g (3.2 oz) |
Please note: The following shows notable compatibility information. It is not a comprehensive list of all compatible products.
Product | Compatible | Note |
---|---|---|
CR1000 (retired) | ||
CR300 | ||
CR3000 (retired) | ||
CR310 | ||
CR350 | ||
CR6 | ||
CR800 (retired) | ||
CR850 (retired) |
A 2.5-ft cable is supplied with the sensor for connection to the data logger. The cable connects to a control port, single-ended analog input terminal, 12 V power terminal, and ground terminal on the data logger.
The CS106 is typically mounted next to the data logger inside an ENC12/14 or larger enclosure. The very small ENC100 is available for housing the CS106 separately, in its own enclosure.