| Services Available | |
|---|---|
| Repair | No |
| Free Support | Yes |
The 092, manufactured by Met One, is a barometric pressure sensor that is commonly used with the WMS100 for wind-farm power performance measurements. It has a polycarbonate casing and a metal weather shield, so it is rugged and weatherproof. It can be used indoors or outdoors, and it provides digital and analog outputs.
Please note: The following shows notable compatibility information. It is not a comprehensive list of all compatible products.
| Product | Compatible | Note |
|---|---|---|
| CR1000 (retired) | ||
| CR1000X (retired) | ||
| CR200X (retired) | ||
| CR206X (retired) | ||
| CR211X (retired) | ||
| CR216X (retired) | ||
| CR300 (retired) | ||
| CR3000 (retired) | ||
| CR310 | ||
| CR350 | ||
| CR5000 (retired) | ||
| CR6 | ||
| CR800 (retired) | ||
| CR850 (retired) | ||
| CR9000X (retired) |
The 092 includes in a small polycarbonate enclosure with metal weather shield. It may be mounted outside or inside a building
| Measurement Description | Barometric pressure |
| Signal Type/Output | Analog voltage |
| -NOTE- | 1 hPa = 1 mBar |
| Pressure Range | 600 to 1100 hPa |
| Elevation | Sea level to 3048 m (10,000 ft) |
| Resolution | 0.1 hPa |
| Long-Term Stability | ±1.0 hPa in 1 year |
| Analog Output | 0 to 1 Vdc, 0 to 2 Vdc, 0 to 2.5 Vdc, or 0 to 5 Vdc (Analog output automatically adjusts from zero to full scale for range selected.) |
| Digital Output | RS-232, RS-485, and SDI-12 |
| Digital Protocol | ASCII Terminal Mode, RTU for RS-232 and RS-485 |
| Baud Rates | 1200, 2400, 4800, 9600, 19.2k bps |
| Current Consumption | 10 mA @ 12 Vdc (typical) |
| Power Range | 6 to 16 Vdc |
| Temperature Range | -40° to +55°C |
| Elevation | ~609.6 m (2,000 ft) below sea level (as in a mine) to 3,657.6 m (12,000 ft) above sea level |
| Accuracy |
|
| Dimensions | 12.0 x 8.0 x 5.5 cm (4.72 x 3.14 x 2.16 in.) |
| Weight | 250 g (8.8 oz) |