Services Available | |
---|---|
Repair | Yes |
Calibration | No |
Free Support | Yes |
The CR295X is a small, low-cost datalogger that reads input from one or two sensors, then transmits the data using the GOES satellite transmitter. Multiple CR295Xs can be configured as a network, or units can be deployed individually. CRBasic, its full programming language, supports simple or complex programming and many onboard data reduction processes. It supports stand-alone operation in harsh, remote environments.
Read MoreThe CR295X includes an additional RS-232 serial port that allows communications with the TX320, TX312, or SAT HDR GOES satellite transmitter. It has several input channels for measuring a variety of sensors. Gas discharge tubes provide rugged electrostatic discharge protection for the inputs.
The CR295X does not make differential measurements and is not compatible with SDM devices, multiplexers, or thermocouples. (Refer to the Compatibility information on the web page for compatible sensors, peripherals, and software.) Recalibration services are not offered for the CR295X dataloggers.
-NOTE- | Note: Additional specifications are listed in the CR200X-Series Specifications Sheet. |
Maximum Scan Rate | 1 Hz |
Analog Channels |
|
Pulse Count Channels | 2 |
Switched Excitation Channels | 2 voltage |
Digital Ports |
|
Communication Ports | 2 RS-232 |
Switched Battery Port | 1 |
Input Voltage Range | 0 to 2500 mV |
Analog Voltage Accuracy | ±(0.25% of reading + (1.2 mV)x(offset)) at -40° to +50°C |
Analog Voltage Resolution | 0.6 mV |
A/D Bits | 12 |
Operating Temperature | -40° to +50°C |
Power Requirements | 7 to 16 Vdc |
Typical Current Drain |
|
Protocols Supported | PakBus (leaf node only), SDI-12 |
Warranty | 3 years |
Dimensions | 14.0 x 7.6 x 4.8 cm (5.5 x 3.0 x 1.9 in.) |
Weight | 242 g (8.5 oz) |
Memory |
|
Final Storage | 512 kB of flash memory for approximately 125,000 data points |
Operating System | 106 kB of flash memory |
Intermediate Storage | 8 kB of SRAM for communication buffers, calculations, variables, etc. |
Please note: The following shows notable compatibility information. It is not a comprehensive list of all compatible products.
Product | Compatible | Note |
---|---|---|
014A-L | ||
03002-L | ||
03101-L | ||
034B-L | ||
05103-45-L (retired) | ||
05103-L | ||
05106-L (retired) | ||
05305-L | ||
083E-L (retired) | ||
092-L (retired) | ||
107 | ||
108 | ||
109 | ||
109SS-L | ||
110PV-L (retired) | ||
237-L (retired) | ||
255-100 | ||
27106T-L | ||
43347-L | ||
52202-L | ||
A100LK-L | ||
CMP11-L (retired) | ||
CMP21-L | ||
CMP6-L (retired) | ||
CS100 | ||
CS106 | ||
CS215-L (retired) | ||
CS300-L (retired) | ||
CS410-L (retired) | ||
CS451 | ||
CS456 | ||
CS460-L (retired) | ||
CS470 (retired) | ||
CS471 (retired) | ||
CS475A-L | ||
CS475-L (retired) | ||
CS511-L | ||
CS526-L (retired) | ||
CS547A-L | ||
CS616 | ||
CS625 (retired) | ||
CS650 | ||
CS655 | ||
CS700-L | ||
CSAT3 (retired) | ||
CSIM11-L | ||
CSIM11-ORP-L | ||
ENVIROSCAN (retired) | ||
HC2S3-L (retired) | ||
HMP155A-L | ||
HMP60-L | ||
LI190SB-L (retired) | ||
LI200X-L (retired) | ||
LWS-L | ||
OBS-3+ (retired) | ||
OBS300 (retired) | ||
OBS500 (retired) | ||
P2546A-L | ||
SEN12512 (retired) | ||
SR50A-L (retired) | ||
TB4-L | ||
TB4MM-L | ||
TE525-L | ||
TE525MM-L | ||
TE525WS-L | ||
WINDSONIC1-L | ||
WINDSONIC4-L | ||
WXT520 (retired) |
Product | Compatible | Note |
---|---|---|
LoggerNet | Version 2.1 or higher | |
PC200W (retired) | ||
PC400 | Version 1.0 or higher | |
PCONNECT (retired) | Version 3.0 or higher | |
PCONNECTCE (retired) | Version 2.0 or higher | |
Short Cut | ||
VISUALWEATHER | Version 2.0 or higher |
The CR295X is compatible with our TX320, TX312 (retired), and SAT HDR GOES (retired) satellite transmitters.
The CR295X can communicate with a PC via direct connect, NL201 Network Link Interface, NL240 Wi-Fi Network Link, MD485 multidrop modem, and digital cellular modems. Data can be viewed on an iOS device, an Android device, CD295 DataView II Display, or a user-supplied PDA. To use an iOS or Android device, go to the Apple Store or Google Play and download our LoggerLink Mobile Apps free of charge. User-supplied PDAs require either PConnect or PConnectCE software.
Campbell Scientific’s SDM devices and multiplexers are not supported.
Typical power supply is a BP12 12 Ahr or BP24 24 Ahr battery, CH100 or CH200 regulator, and an SP10 or SP20 solar panel. The CR295X includes a cable for connecting it with the satellite transmitter and power supply.
An ENC16/18 enclosure can house the CR295X logger, satellite transmitter, and power supply; smaller enclosures cannot house the power supply required for GOES communications. Hardware is included with the data logger for mounting to an enclosure backplate.
The CR295X can measure a variety of sensors including SDI-12 sensors and 4 to 20 mA sensors. It cannot make differential measurements and is not compatible with the freezing-rain/ice, fuel moisture/temperature, geographic position, present weather, soil heat flux, soil matric water potential, and strain sensors listed on our price lists.
Execution of this download installs the Operating System and Compiler on your computer for the following dataloggers:CR200X, CR206X, CR211X, CR216X and CR295X. It also updates the support files for the CRBasic Editor.
Note: Newer CR206X dataloggers (serial # ≥ 19122) and newer CR211X dataloggers (serial # ≥ 19143) have 250 mW radios that must use OS 3 or higher for their datalogger operating system.
Number of FAQs related to CR295X: 1
The CR200X-series and the retired CR200-series dataloggers are NOT compatible with SDMs or multiplexers. If more channels are needed or may be needed in the future, consider purchasing a CR800, CR850, or CR1000 instead.