Services Available | |
---|---|
Repair | No |
Calibration | No |
Free Support | No |
Campbell Scientific’s ST-21 is a Service Argos-certified Platform Transmitter Terminal (PTT ) that transfers data from the datalogger site to the Argos Data Collection and Location System via NOAA polar orbiting satellites. This transmitter is well suited for remote meteorological and environmental data collection applications, including mobile and high-latitude installations. The ST-21 is compatible with our newer dataloggers.
Read MoreWhile Campbell Scientific's ST-21 Argos PTT is based on Telonics' ST-21, they are not equivalent; our ST-21 includes a case, voltage regulator, and our SDC communication interface.
Please note that when ordering the transmitter, the customer needs to provide Campbell Scientific with the number of buffers, repetition rate, decimal ID, Dex ID, frequency, and fail safe information.
To use the Argos system, you must receive formal permission from Service Argos and pay a fee. The data must be used for environmental purposes. Examples include meteorological/hydrological stations, ship tracking, volcano monitoring, and seismic data.
Choose one of the following methods:
Operating Temperature Range | -30° to +70°C |
Supply Voltage | 12 V (nominal) |
Output Impedance | 50 Ω |
High Power Level | 800 mW typical (27 to 31 dbm) |
Argos Transmission Frequency | 401.618 to 401.680 MHz |
Modulation (BPSK) | -1.1 to +1.1 ±0.1 radians |
Spurious Emissions | -45 dB |
Transmission Distance or Area | Worldwide |
Current Drain |
|
Service Requirements | Must receive formal permission from Service Argos and pay a fee. Must use data for environmental purposes. |
Dimensions | 19.05 x 3.18 x 5.72 cm (7.5 x 1.25 x 2.25 in.) |
Weight | 224 g (7.9 oz) |
Please note: The following shows notable compatibility information. It is not a comprehensive list of all compatible products.
Product | Compatible | Note |
---|---|---|
CR1000 (retired) | ||
CR1000X | ||
CR200X (retired) | ||
CR206X (retired) | ||
CR211X (retired) | ||
CR216X (retired) | ||
CR295X (retired) | ||
CR300 | ||
CR3000 (retired) | ||
CR5000 (retired) | ||
CR6 | ||
CR800 (retired) | ||
CR850 (retired) | ||
CR9000X (retired) |
Our data loggers can format the data as bits per data point, allowing the user to select the resolution used for each data point.
The ST-21 requires a desiccated, non-condensing environment; a Campbell Scientific enclosure is recommended. Grommets and screws are provided to attach the ST-21's flanges to the backplate of our enclosures.
To subscribe to Argos, the following steps must be completed:
Number of FAQs related to ST-21: 1
No, the ST-21 and the retired ST-20 are for use with the CR800, CR1000, and the CR3000.