The SC115 is a lightweight, portable, 2 GB device that allows you to augment your onsite data storage or to transport data between the datalogger and PC. It is the only external storage device compatible with the CR800 and CR850 dataloggers.
Read MoreThe SC115 consists of electronics protected in a custom molded package. It has a USB 2.0 compatible connector for attaching it to the PC's USB port, and a CS I/O 9-pin connector for attaching it to a data logger's CS I/O port. The SC115 may be connected directly to a PC or data logger, or connected through the supplied extension cables.
The SC115 is typically used as an external data storage device, but may also be used as a USB-to-CS I/O synchronous device communications (SDC) adapter. As a USB-to-CS I/O adapter, the SC115 supports direct communication between a Campbell Scientific data logger and a PC equipped with a USB port. However, the SC115 is not electronically isolated, and therefore is better for temporary communications with a battery-powered PC. Another device, the SC-USB, also supports direct communications with a PC's USB port, but is optically isolated.
USB drivers for the SC115 must be installed before connecting the SC115 to a PC for configuration or as a USB-to-CS I/O adapter. The driver can be installed from the Device Configuration Utility device page by clicking the "Install the Device Driver" link.
Storage Capacity | 2 GB |
Power Requirements | 12 V (supplied through the PC’s USB port or the data logger’s CS I/O port) |
Typical Current Drain |
|
Temperature Range | -25° to +50°C |
Packaging | Overmolded with thermoplastic polymide |
Connectors | USB 2.0 compatible, CS I/O 9-pin |
Dimensions | 10.54 x 4.32 x 1.78 cm (4.15 x 1.7 x 0.7 in.) |
Weight | 63.79 g (2.25 oz) |
Please note: The following shows notable compatibility information. It is not a comprehensive list of all compatible products.
Product | Compatible | Note |
---|---|---|
CR1000 (retired) | ||
CR1000X | ||
CR200X (retired) | ||
CR206X (retired) | ||
CR211X (retired) | ||
CR216X (retired) | ||
CR295X (retired) | ||
CR300 | ||
CR3000 (retired) | ||
CR310 | ||
CR350 | ||
CR5000 (retired) | Beginning with OS version 6, the SC115 is compatible with the CR5000. | |
CR6 | ||
CR800 (retired) | ||
CR850 (retired) | ||
CR9000X (retired) | Beginning with OS version 6, the SC115 is compatible with the CR9000X. |
Product | Compatible | Note |
---|---|---|
Granite 10 | ||
Granite 6 | ||
Granite 9 |
The SC115 has a CS I/O port for attachment to the data logger and a USB port for attachment to a PC. You can connect the SC115 to the PC or data logger either directly or via the supplied cables. (Only one SC115 can be connected to a data logger at a time.) An SC12 CS I/O cable and a USB cable are shipped with the SC115.
CRBasic TableFile instruction is used to store data to the drive. Our Device Configuration (DevConfig) utility can be used for field configuration, OS download, and setting the SDC address. CRBasic and DevConfig are included in LoggerNet and PC400 Datalogger Support Software.
Windows USB drivers for the SC115 are installed via the Device Configuration Utililty. In the Device Configuration Utility, click on the link "install the device driver for the SC115" in the main body of text for the SC115.
Current version of the SC115 Operating System. Requires the Device Configuration Utility to upload the operating system to the SC115.
Note: Windows USB drivers for the SC115 can be install via the Device Configuration Utililty. Click on the link "install the device driver for the SC115" in the main body of text for the SC115.