Overview

The RF411 has a 920 to 928 MHz frequency range, which is used in Australia and Israel. This 100 mW spread-spectrum radio can transmit data to another RF411 radio, an RF431 radio, a CR211(X) datalogger, or an AVW211 interface.

The RF411 supports point-to-point and point-to-multipoint communications. It can serve as a field modem/radio while connected to the datalogger or as a base station modem/radio while connected to a computer. The radio can also serve as a stand-alone RF router/repeater.

Read More

Benefits and Features

  • Rugged, low-cost transceivers
  • Can be used in the field as a transceiver or in the office as the base station
  • Transmits up to one mile with omnidirectional antenna; up to 10 miles with higher gain directional antennas at ideal conditions
  • Settings stored in non-volatile memory
  • RS-232 port for connecting to a computer; CS I/O port for connecting to a data logger
  • Frequency-hops over 25 channels avoids interference from other spread-spectrum radios
  • Optional extended temperature testing
  • Faster communication due to elimination of some small "link state packets"
  • Ability to have stand-alone RF router/repeaters (up to 8 repeaters)
  • Greater immunity to interference and RF collisions by using RF retries
  • Reduced power consumption by the data logger, as the radios perform "packet address filtering"
  • Built-in setup menus allow access to advanced functionality
  • Designed for use in PakBus networks

Detailed Description

The RF411 reduces susceptibility to RF interference from other spread spectrum devices by providing user-selectable frequency hopping patterns. Spread spectrum radios spread the normally narrowband information signal over a relatively wide band of frequencies. This process allows communications to be more immune to noise and interference from RF sources such as pagers and cellular phones.

Specifications

Operating Frequency 920 to 928 MHz
Type Frequency Hopping Spread Spectrum (FHSS) Transceiver
RS-232 Data Rate 38.4k, 19.2k, 9600, 4800, or 1200 bps
Channel Capacity 65,000 Network Identifiers share 25 hop channels.
Frequency Hopping Patterns Six different selectable patterns
Receiver Sensitivity -110 dBm at 10-4 bit error rate (Campbell Scientific protocols will issue retries wherever a bit error occurs.)
Interference Rejection 70 dB at pager and cellular phone frequencies
Transmitter Power Output 100 mW (nominal)
Antenna Connector Reverse polarity SMA
FCC ID OUR9XTREAM
Power 9 to 16 Vdc
LEDs Power on, TX, RX, diagnostics
RS-232 Connector 9-pin “D” female (4 wire: Tx, Rx, CTS, GND)
CS I/O Connector 9-pin “D” male

Newer dataloggers supply power to the RF411 radio on this connector. Dataloggers purchased before December 1997 require the pn 14291 Field Power Cable.
Power Connector Barrel plug, center positive 12 V (used to connect the 14291 Field Power Cable)
Maximum Nodes in Network 50
Standard Operating Temperature Range -25° to +50°C
Extended Operating Temperature Range -55° to +85°C

The push button that allows you to check/edit programmable settings while the radio is connected to a computer may not operate at temperatures colder than -25°C.
Dimensions 11.4 x 7.0 x 2.9 cm (4.9 x 2.8 x 1.2 in.)
Weight 227 g (8 oz)

Average Current Drain

Standby < 1 mA (power-saving options used)
Receiving 24 mA
Transmitting < 75 mA

Compatibility

Please note: The following shows notable compatibility information. It is not a comprehensive list of all compatible products.

Dataloggers

Product Compatible Note
21X (retired)
CR10 (retired)
CR1000 (retired)
CR1000X
CR10X (retired)
CR200X (retired)
CR206X (retired)
CR211X (retired)
CR216X (retired)
CR23X (retired)
CR295X (retired)
CR300
CR3000 (retired)
CR500 (retired)
CR5000 (retired)
CR510 (retired)
CR6
CR800 (retired)
CR850 (retired)
CR9000 (retired) Although the CR9000 and CR9000X are compatible, RF411 radios do not support their fastest communication rates, and are therefore not practical for many CR9000(X) applications.
CR9000X (retired) Although the CR9000 and CR9000X are compatible, RF411 radios do not support their fastest communication rates, and are therefore not practical for many CR9000(X) applications.

Mounting Equipment

Product Compatible Note
ENC10/12
ENC10/12R
ENC12/14
ENC14/16
ENC16/18

Additional Compatibility Information

Communications

Internal Radio of CR211(X) Dataloggers

The RF411 spread spectrum radio can communicate with the internal spread spectrum radio of our CR211(X) dataloggers. Certain RF411 settings must match the CR211(X) settings for communications between the radio and data logger to be successful. The factory default settings of these devices may not match; therefore, they may need to be reconfigured before communications can take place. For more information, refer to the Quick Reference Guide for Setting Up RF401-to-CR206 Communication application note (see Documents).

Other Spread-Spectrum Radios

The RF411 radios can be used in networks containing RF431 and RF410 radios. When RF411 radios are used in networks containing RF400 radios, the Protocol must be set to Transparent. Also, if RF410 and RF411 radios will be in the same RF proximity, do not use 28, 44, 52, 56, or 60 for the RF410 Net Address. RF410 radios with Net Addresses of 28, 44, 52, and 56 interfere with RF411 radios with Net Addresses of 0, 1, 2, and 3, respectively. The RF410 Net Address of 60 interferes with all RF411 Net Addresses.

Campbell Scientific does not recommend using the RF411 in networks containing FGR-115 or RF450 radios.

Transparent and PakBus Protocols

Do not mix RF411 radios set to the Transparent protocol with RF411 or RF431 radios set to either of the PakBus protocols, since this will produce RF traffic without any RF communications. However radios with the PakBus Aware and PakBus Node settings can coexist in the same network (i.e., some radios set to PakBus Aware and some radios set to PakBus Node).

Enclosure Considerations

A desiccated, non-condensing environment is required. The 14162 Mounting Kit includes hardware for securing the RF411 to an enclosure backplate (see Ordering Info).