Overview

The PWENC16/18 is a prewired, weather-resistant enclosure that is 16 in. wide and 18 in. tall. It starts with the same enclosure used for our ENC16/18, but then is factory configured with up to 19 connectors that are attached to the datalogger or peripherals within the enclosure. Sensors with the appropriate connector are simply attached to connectors on the outside of the enclosure. Campbell Scientific even creates a custom datalogger program.

Read More

Benefits and Features

  • Weather resistant to protect instruments
  • Backplate designed so that Campbell Scientific components mount easily and securely
  • Combines flexibility with ease of use
  • Eliminates the task of wiring sensor leads into the data logger’s terminal strips
  • Reduces wiring errors by inexperienced field technicians who are unfamiliar with the equipment
  • Shortens deployment time
  • Allows each enclosure in a large network to be similar to the other enclosures
  • Customized options may be purchased
  • White, UV-stabilized enclosure reflects solar radiation—reducing temperature gradients inside the enclosure without requiring a separate radiation shield

Detailed Description

The PWENC16/18 can house one datalogger, power supply, and one or more peripheral (depending on the peripheral’s footprint). You order the sensors, datalogger, power supply, and communication peripherals separately. Compatible sensors, peripheral cables, and solar panels have a –PW extension. 

The PWENC16/18 is shipped with the 7363 enclosure supply kit that consists of desiccant, a humidity indicator card, cable ties, wire tie tabs, putty, grommets, screws, and PVC coupling. Connectors, communication ports, and the enclosure mounting bracket are chosen as options. (See Ordering Info on the web page.)

The PWENC16/18 can be mounted to any of our tripods or towers, or to a user-supplied pipe.

Note: Refer to the Ordering Info on the web page for standard configurations. Nonstandard configurations must be special ordered. It is considered a nonstandard configuration when using a different type, size, or location for any connector, communication port, conduit, cable entry seal, or antenna bulkhead (contact Campbell Scientific for more information).

Specifications

Color White (Reflects solar radiation, reducing temperature gradients inside the enclosure without using a separate radiation shield.)
Construction Fiberglass-reinforced polyester enclosure with door gasket, external grounding lug, stainless-steel hinge, and lockable hasps
Enclosure Classification NEMA 4X (before being modified for cable entry)
Dimensions
  • 45.7 x 40.6 x 22.9 cm (18 x 16 x 9 in.) internal
  • 43.8 x 38.7 x 25.2 cm (17.3 x 15.3 x 9.9 in.) internal under the lid space
  • 49.5 x 44.4 x 27 cm (19.5 x 17.5 x 10.6 in.) external
Weight 7.7 kg (17 lb)

Compatibility

Please note: The following shows notable compatibility information. It is not a comprehensive list of all compatible products.

Dataloggers

Product Compatible Note
21X (retired)
CR10 (retired)
CR1000 (retired)
CR1000X
CR10X (retired)
CR200X (retired)
CR206X (retired)
CR211X (retired)
CR216X (retired)
CR23X (retired)
CR295X (retired)
CR300
CR3000 (retired)
CR310
CR350
CR500 (retired)
CR5000 (retired)
CR510 (retired)
CR6
CR800 (retired)
CR850 (retired)
CR9000 (retired)
CR9000X (retired)

Additional Compatibility Information

Peripherals

Our prewired enclosures can house any peripheral that our standard enclosures can house. Equipment that can be attached to the outside of the prewired enclosure include:

  • Sensors—models with an -PW extension are compatible; a -PW version is available for most Campbell Scientific sensors.
  • Digital camera—the cable used to connect a CC5MPX or CC5MPXWD high-resolution digital camera has a -PW cable termination option.
  • AC wall charger—the 22110 Wall Charger (accepts 110  to 240 Vac) has the appropriate connector.
  • Solar panels—Campbell Scientific offers -PW versions of our 10 W, 20 W, 50 W, and 90 W solar panels.
  • Keyboard display—the CR1000KD can be connected via an optional CS I/O port.
  • Laptop—an RS-232 or CS I/O port can be added to the outside of the enclosure allowing laptop connection.
  • Ethernet cable—an optional Ethernet port is offered that supports communications over a local network or a dedicated Internet connection.
  • Antennas—the outside of the enclosure can include connectors for attaching antenna cables.
  • Measurement and control peripherals—cables used to connect our SDMs and multiplexers come in -PW versions.

Frequently Asked Questions

Number of FAQs related to PWENC16/18: 1

  1. If you purchased a Stahlin enclosure from Campbell Scientific and it has a failed gasket, we can help you. We will need you to provide an image of the failed gasket, verify the size of your enclosure, and provide your contact information. We can then arrange to have a replacement gasket sent to you from Stahlin. For assistance, contact Technical Support at 435.227.9100.