Services Available | |
---|---|
Repair | Yes |
Calibration | No |
Free Support | Yes |
La NL120 le permite al Datalogger comunicarse sobre una red local o a una conexión de Internet dedicada. Se utiliza el protocolo TCP/IP. Este dispositivo esta diseñado para conectarse al puerto de periféricos de 40 pines disponible en el CR1000 o en el CR3000.
Read MoreThe NL120 uses a straight through cable when the cable is run from a hub to the NL120. A 10baseT Ethernet crossover cable is used if the cable is run directly from the computer to the NL120. For cable lengths longer than 9 feet, either a shielded 10baseT Ethernet cable or the 28033 surge protector needs to be used.
The NL120 is set up using the Device Configuration utility (DevConfig). DevConfig is bundled with our PC400, RTDAQ, and LoggerNet software and is available, at no charge, from: www.campbellsci.com/downloads
Power Requirements | 12 V (supplied through the data logger’s peripheral port) |
Ethernet Speed | 10Base-T (10 Mbps), half-duplex |
Typical Current Drain | 20 mA |
Dimensions | 10.2 x 6.4 x 2.8 cm (4.0 x 2.5 x 1.1 in.) |
Weight | 66.62 g (2.35 oz) |
EMI and ESD Protection |
|
European Standards | Meets requirements for a class A device under European Standards. |
Application of Council Directive(s) | 89/336/EEC as amended by 89/336/EEC and 93/68/EEC |
Standards to Which Conformity Is Declared | EN55022-1; 1995 and EN50082-1: 1992 |
Software Requirements |
|
LoggerNet | Version 3.2 or later |
PC400 | Version 1.3 or later |
DevConfig | Version 1.5 or later |
Please note: The following shows notable compatibility information. It is not a comprehensive list of all compatible products.
Product | Compatible | Note |
---|---|---|
CR1000 (retired) | ||
CR200X (retired) | ||
CR206X (retired) | ||
CR211X (retired) | ||
CR216X (retired) | ||
CR295X (retired) | ||
CR3000 (retired) | ||
CR5000 (retired) | ||
CR800 (retired) | ||
CR850 (retired) | ||
CR9000X (retired) |
Product | Compatible | Note |
---|---|---|
ENC10/12 | ||
ENC10/12R | Attached to a CR1000 or CR3000 | |
ENC12/14 | Attached to a CR1000 | |
ENC14/16 | Attached to a CR1000 or CR3000 | |
ENC16/18 | Attached to a CR1000 or CR3000 |
A 10baseT Ethernet straight through cable is used when the cable is run from a hub to the NL120. A 10baseT Ethernet crossover cable is used if the cable is run directly from the computer to the NL120. For cable length longer than 9 ft, the 10baseT Ethernet cable must be shielded or the 28033 surge suppressor must be used.
The NL120 fastens onto the data logger's 40-pin peripheral port. This means that the NL120 is only compatible with the CR1000 and CR3000. It is NOT compatible with the CR800, CR850, CR200X, CR5000, or CR9000X dataloggers.
Number of FAQs related to NL120: 1
Yes. For example, the NL115 allows the CR1000 to communicate over a local network or a dedicated Internet connection via TCP/IP.