CSAT3A 3-D Sonic Anemometer, Head Only
Precision Measurements
Best instrument for flux and other high-level turbulence research projects
weather aplicaciones soportadas water aplicaciones soportadas energy aplicaciones soportadas gas flux and turbulence aplicaciones soportadas infrastructure aplicaciones soportadas soil aplicaciones soportadas

Overview

The CSAT3A sonic anemometer head is similar to the sensor head from the CSAT3 sonic anemometer, but its cable is modified to connect to the EC100 electronics. It is used as part of the EC150 open-path analyzer and the CPEC200 closed-path eddy-covariance system.

Read More

Benefits and Features

  • New conformal coating helps protect sonic transducers in corrosive environments
  • Innovative design provides precision turbulence measurements with minimal flow distortion
  • Usually combined with EC150 or EC155 gas analyzers giving near complete colocation for eddy-covariance measurements
  • Compatible with most Campbell Scientific data loggers
  • Measurements can be used to calculate momentum flux and friction velocity
  • Campbell Scientific’s fine wire thermocouples are an option for fast-response temperature measurements
  • Field rugged
  • Innovative signal processing and transducer wicks considerably improve performance of the anemometer during rain events
  • Sealed sonic transducers and electronics

Images

CSAT3A lower transducer assembly top view

Detailed Description

The CSAT3A is an optional component of an EC150 open-path or EC155 closed-path CO2/H2O gas analyzer. It attaches to a common mounting bracket and connects to the gas analyzer's EC100 electronics module.

Specifications

Measurement Path Length
  • 10.0 cm (3.94 in.) vertical
  • 5.8 cm (2.3 in.) horizontal
Path Angle from Horizontal 60°
Construction Sealed sonic transducers and electronics
Anemometer Head Materials Stainless-steel tubing
Electronics Box Materials Welded aluminum
Operating Temperature Range -30° to +50°C
Voltage Supply 10 to 16 Vdc
Current
  • 200 mA (60 Hz measurement rate)
  • 100 mA (20 Hz measurement rate)
Digital SDM Output Signal CSI 33.3 k baud serial interface for data logger/sensor communication. (Data type is 2-byte integer per output plus 2-byte diagnostic.)
Support Arm Diameter 1.59 cm (0.63 in.)
Transducer Diameter 0.64 cm (0.25 in.)
Transducer Mounting Arm Diameter 0.84 cm (0.33 in.)
Anemometer Head Dimensions 47.3 x 42.4 cm (18.6 x 16.7 in.)
Anemometer Head Weight 1.7 kg (3.7 lb)

Measurements

Outputs ux, uy, uz, c
(ux, uy, uz are wind components referenced to the anemometer axes; c is speed of sound.)
Speed of Sound Determined from three acoustic paths; corrected for crosswind effects.
Measurement Rate Programmable from 1 to 60 Hz, instantaneous measurements. Two over-sampled modes are block averaged to either 20 Hz or 10 Hz.
Output Bandwidths 5, 10, 12.5, or 20 Hz
Output Rate 10, 20, 25, or 50 Hz
Measurement Resolution
  • Resolution values are for instantaneous measurements made on a constant signal; noise is not affected by sample rate.
  • 1 mm/s rms (ux, uy)
  • 0.5 mm/s rms (uz)
  • 15 mm/s (0.025°C) rms (c)
Offset Error
  • Offset error and gain error values assume the -30° to +50°C range, wind speeds of < 30 m/s, and wind angles between ±170°.
  • < ±8.0 cm/s (ux, uy)
  • < ±4.0 cm/s (uz)
Gain Error
  • Offset error and gain error values assume the -30° to +50°C range, wind speeds of < 30 m/s, and wind angles between ±170°.
  • < ±2% of reading (wind vector within ±5° of horizontal)
  • < ±3% of reading (wind vector within ±10° of horizontal)
  • < ±6% of reading (wind vector within ±20° of horizontal)
Rain Innovative ultrasonic signal processing and user-installable wicks considerably improve the performance of the anemometer under all rain events.

Digital USB and RS-485 Output Signal

Baud Rate 230400 bps (maximum)
Data Type Comma-delimited ASCII

SDM, USB, & RS-485 Digital Outputs Reporting Range

Full-Scale Wind ±65.535 m/s autoranging between four ranges (Least significant bit is 0.25 to 2 mm/s.)
Speed of Sound 300 to 366 m/s (-50° to +60°C) Least significant bit is 1 mm/s (0.002°C).

Compatibility

Please note: The following shows notable compatibility information. It is not a comprehensive list of all compatible products.

Dataloggers

Product Compatible Note
CR1000 (retired)
CR200X (retired)
CR206X (retired)
CR211X (retired)
CR216X (retired)
CR295X (retired)
CR3000 (retired)
CR5000 (retired)
CR800 (retired)
CR850 (retired)
CR9000X (retired)

Frequently Asked Questions

Number of FAQs related to CSAT3A: 1

Casos de estudio

Korea: Flux Monitoring over a Rice Paddy
With instrumentation and help from Campbell Scientific, personnel from the Department of Atmospheric Sciences at......read more