The 27106T Vertical Propeller Anemometer is a low threshold precision air velocity sensor that is especially suited for monitoring the vertical wind component. It connects directly to a Campbell Scientific datalogger, which measures the 27106T signal and converts the signal to engineering units (mph, m/s, knots).
Read MoreThe 27106T, manufactured by R. M. Young, measures air velocity using a fast-response, four-blade helicoid propeller that drives a high quality tech-generator transducer. The transducer converts the propeller’s rotation to a DC voltage that is linearly proportional to air velocity.
The 27106T should be oriented with the propeller facing the predominant flow of air being measured. Its propeller responds only to the component of the air flow, which is parallel to the axis of its rotation. Off-axis response closely approximates a cosine curve with appropriate polarity. With perpendicular air flow, the propeller does not rotate.
Sensor | Helicoid-shaped, 4-blade propeller |
Measurement Description | Vertical wind speed |
Signal Type/Output | Analog voltage |
-NOTE- | Threshold and distance constant values are for axial flow. |
Threshold Sensitivity | 0.4 m s-1 (0.8 mph) |
Distance Constant | < 2.1 m (6.9 ft) |
Pitch | 30.0 cm (11.8 in.) air passage per revolution |
Output |
Analog dc voltage proportional to axial wind component. Polarity reverses with reverse rotation. 1800 rpm (500 mV) = 9.0 m/s (20.1 mph) |
Operating Temperature Range | -50° to +50°C |
Range |
|
Propeller Description | 4-blade helicoid propeller molded of carbon fiber thermoplastic |
Compliance with Standards |
|
Propeller Diameter | 20 cm (8 in.) |
Housing Diameter | 2.5 cm (1 in.) |
Length | 43 cm (17 in.) |
Weight | 0.5 kg (1.2 lb) |
Please note: The following shows notable compatibility information. It is not a comprehensive list of all compatible products.
Product | Compatible | Note |
---|---|---|
CR1000 (retired) | ||
CR1000X | ||
CR300 | ||
CR3000 (retired) | ||
CR350 | ||
CR6 | ||
CR800 (retired) | ||
CR850 (retired) |
The 27106T is shipped with a 3/4 inch IPS threaded pipe for mounting. The pipe can be attached to a CM202, CM202SS, CM203, CM204, CM204SS, or CM206 crossarm using a 1049 Nu-Rail fitting or CM220 Right-Angle Mounting Bracket.
The 27106T includes a connector/coupler that mates to the sensor and to the 3/4-inch IPS threaded pipe. The customer specified length of cable is soldered to the pins on the connector and the cable threads through the coupler and out the pipe.