The AVW206 is a vibrating wire analyzer module that includes an internal 910 to 918 MHz spread-spectrum radio for wireless communication, typically used in the U.S. and Canada. With this vibrating wire analyzer module, your data logger can measure vibrating wire strain gages, pressure transducers, piezometers, tiltmeters, crackmeters, and load cells. These sensors are used in a wide variety of structural, hydrological, and geotechnical applications because of their stability, accuracy, and durability.
Read MoreThe AVW206 uses vibrating wire spectral-analysis technology (VSPECT®). VSPECT® observes the incoming sensor signal, performs a Fourier transform and a spectral analysis (transforming the time series into individual sinusoidal components in the frequency spectrum), and determines the sensor frequency by identifying the largest signal in the acceptable range while filtering out environmental and electrical noise.
The AVW206 analyzer module also provides many self-checking diagnostics such as vibrating element signal strength, signal-to-noise ratio, vibrating element signal decay ratio, and incorrect signal response. These diagnostics can be running in the background to give continual feedback of the condition for each sensor.
The AVW206 typically transmits its data to an RF401(A) spread-spectrum radio that is connected to the data logger. The AVW206 can also be connected directly to the data logger.
-NOTE- | Electrical specifications are valid over a -25° to +50°C range unless otherwise specified. Non-condensing environment required. |
Internal Radio Frequency Range | 910 to 918 MHz |
Radio Power |
250 mW Older AVW206 modules (serial # < 11224) have 100 mW radios. |
Number of Vibrating Wire Sensors Measured | Up to 2 vibrating wire sensors can be connected to the analyzer module. Additional sensors can be measured by using an AM16/32-series multiplexer. |
Power Requirements | 9.6 to 16 Vdc |
Analog Input/Outputs | 2 differential (DF) vibrating wire measurements (V+ and V-) and 2 single-ended (SE) ratiometric resistive half-bridge measurements (T+ and T-) for vibrating wire sensor's onboard temperature sensor. |
Digital Control Ports |
3 digital control ports (C1 – C3)
|
RS-232 Port | 1 9-pin RS-232 port (for connecting to a data logger COM port) |
Measurement Resolution | 0.001 Hz RMS (±250 mV differential input range; -55° to +85°C) |
Measurement Accuracy | ±0.013% of reading (±250 mV differential input range; -55° to +85°C) |
Input Voltage Range | ±250 mV (differential) for vibrating wire inputs |
Common Mode Range | ±25 V |
Baud Rates | Selectable from 1200 to 38.4 kbps (ASCII protocol is one start bit, one stop bit, eight data bits, and no parity.) |
Memory |
|
CE Compliance Standards to which Conformity Is Declared | IEC61326:2002 |
Dimensions | 21.6 x 11.18 x 3.18 cm (8.5 x 4.5 x 1.2 in.) |
Weight | 0.43 kg (0.95 lb) |
Typical Current Drain @ 12 Vdc |
|
Quiescent, Radio Off | ~0.3 mA |
Radio Duty Cycling 1 s | ~3 mA (includes quiescent current) |
Radio Always On | ~26 mA (radio transmit current 100 mA) |
Active RS-232 Communication | ~6 mA (3 s after communication stops, the current will drop to the quiescent current.) |
Measurement | ~25 mA (averaged over the 2 s) |
Please note: The following shows notable compatibility information. It is not a comprehensive list of all compatible products.
Product | Compatible | Note |
---|---|---|
21X (retired) | ||
CR10 (retired) | The CR10 supports the SDI-12 mode only. | |
CR1000 (retired) | ||
CR1000X | ||
CR10X (retired) | The CR10X supports the SDI-12 mode only. | |
CR200X (retired) | ||
CR206X (retired) | ||
CR211X (retired) | ||
CR216X (retired) | ||
CR23X (retired) | The CR23X supports the SDI-12 mode only. | |
CR295X (retired) | ||
CR300 | ||
CR3000 (retired) | ||
CR310 | ||
CR350 | ||
CR500 (retired) | ||
CR5000 (retired) | The CR5000 supports the SDI-12 mode only. | |
CR510 (retired) | ||
CR800 (retired) | ||
CR850 (retired) | ||
CR9000 (retired) | ||
CR9000X (retired) |
Product | Compatible | Note |
---|---|---|
ENC10/12 | If using the RS-232 port, the AVW206 must be mounted flat to fit in an ENC10/12. | |
ENC10/12R | If using the RS-232 port, the AVW206 must be mounted flat to fit in an ENC10/12Rl | |
ENC12/14 | If using the RS-232 port, the AVW206 must be mounted flat to fit in an ENC12/14. | |
ENC14/16 | ||
ENC16/18 | ||
ENC24/30 | ||
ENC24/30S |
The AVW206 Vibrating Wire Spectrum Analyzer Module allows our data loggers to measure vibrating wire strain gages, pressure transducers, piezometers, tiltmeters, crackmeters, and load cells.
The AVW206's internal spread spectrum radio can transmit data to an RF401A, RF401, or RF430. The AVW206 does not have a transparent mode, and therefore its internal radio cannot communicate with an RF400 radio.
The AVW206 requires a desiccated, non-condensing environment. A Campbell Scientific enclosure is recommended when the analyzer module is in the field. The AVW206 has built-in keyhole flanges for mounting to an enclosure backplate.
The AVW206 is typically powered by the data logger's power supply.
Newer modules with 250 mW radios must use OS 5 or higher for their operating system.
Current AVW200 firmware. Use the Device Configuration Utility version 1.13 or greater to send firmware and to configure the AVW200.