Limited Availability ›
This product has limited availability. Some accessories, replacement parts, or services may still be available when it is no longer available.
AVW206 900 MHz Wireless 2-Channel Vibrating Wire Analyzer Module
Greatly Reduces
Signal Noise

Includes built-in radio
weather aplicaciones soportadas water aplicaciones soportadas energy aplicaciones soportadas gas flux and turbulence aplicaciones soportadas infrastructure aplicaciones soportadas soil aplicaciones soportadas

Overview

The AVW206 is a vibrating wire analyzer module that includes an internal 910 to 918 MHz spread-spectrum radio for wireless communication, typically used in the U.S. and Canada. With this vibrating wire analyzer module, your data logger can measure vibrating wire strain gages, pressure transducers, piezometers, tiltmeters, crackmeters, and load cells. These sensors are used in a wide variety of structural, hydrological, and geotechnical applications because of their stability, accuracy, and durability.

Read More

Benefits and Features

  • Provides better measurements by significantly reducing incorrect readings caused by noise sources
  • Interfaces two vibrating wire sensors; more sensors may be connected if an AM16/32B multiplexer is used
  • Self-checking diagnostics give continual feedback on sensor condition
  • High resolution—less than 0.001 Hz (industry standard is 0.1 Hz)
  • Low current drain
  • Remote, wireless operation with on-board radio
  • Interfaces both temperature and frequency measurements from vibrating wire sensors

Images

AVW206 with antenna (sold separately)
AVW206 with antenna (sold separately)
AVW206 with antenna (sold separately)

Detailed Description

The AVW206 uses vibrating wire spectral-analysis technology (VSPECT®). VSPECT® observes the incoming sensor signal, performs a Fourier transform and a spectral analysis (transforming the time series into individual sinusoidal components in the frequency spectrum), and determines the sensor frequency by identifying the largest signal in the acceptable range while filtering out environmental and electrical noise.

The AVW206 analyzer module also provides many self-checking diagnostics such as vibrating element signal strength, signal-to-noise ratio, vibrating element signal decay ratio, and incorrect signal response. These diagnostics can be running in the background to give continual feedback of the condition for each sensor.

The AVW206 typically transmits its data to an RF401(A) spread-spectrum radio that is connected to the data logger. The AVW206 can also be connected directly to the data logger.

Specifications

-NOTE- Electrical specifications are valid over a -25° to +50°C range unless otherwise specified. Non-condensing environment required.
Internal Radio Frequency Range 910 to 918 MHz
Radio Power 250 mW
Older AVW206 modules (serial # < 11224) have 100 mW radios.
Number of Vibrating Wire Sensors Measured Up to 2 vibrating wire sensors can be connected to the analyzer module. Additional sensors can be measured by using an AM16/32-series multiplexer.
Power Requirements 9.6 to 16 Vdc
Analog Input/Outputs 2 differential (DF) vibrating wire measurements (V+ and V-) and 2 single-ended (SE) ratiometric resistive half-bridge measurements (T+ and T-) for vibrating wire sensor's onboard temperature sensor.
Digital Control Ports 3 digital control ports (C1 – C3)
  • C1 functions as an SDI-12 I/O communication port.
  • C2 functions as a Clk output for multiplexer control.
  • C3 functions as a Reset output for multiplexer control.
RS-232 Port 1 9-pin RS-232 port (for connecting to a data logger COM port)
Measurement Resolution 0.001 Hz RMS (±250 mV differential input range; -55° to +85°C)
Measurement Accuracy ±0.013% of reading (±250 mV differential input range; -55° to +85°C)
Input Voltage Range ±250 mV (differential) for vibrating wire inputs
Common Mode Range ±25 V
Baud Rates Selectable from 1200 to 38.4 kbps (ASCII protocol is one start bit, one stop bit, eight data bits, and no parity.)
Memory
  • Either 128 or 512 kB of SRAM
  • 2 MB of OS Flash
CE Compliance Standards to which Conformity Is Declared IEC61326:2002
Dimensions 21.6 x 11.18 x 3.18 cm (8.5 x 4.5 x 1.2 in.)
Weight 0.43 kg (0.95 lb)

Typical Current Drain @ 12 Vdc

Quiescent, Radio Off ~0.3 mA
Radio Duty Cycling 1 s ~3 mA (includes quiescent current)
Radio Always On ~26 mA (radio transmit current 100 mA)
Active RS-232 Communication ~6 mA (3 s after communication stops, the current will drop to the quiescent current.)
Measurement ~25 mA (averaged over the 2 s)

Compatibility

Please note: The following shows notable compatibility information. It is not a comprehensive list of all compatible products.

Dataloggers

Product Compatible Note
21X (retired)
CR10 (retired) The CR10 supports the SDI-12 mode only.
CR1000 (retired)
CR1000X
CR10X (retired) The CR10X supports the SDI-12 mode only.
CR200X (retired)
CR206X (retired)
CR211X (retired)
CR216X (retired)
CR23X (retired) The CR23X supports the SDI-12 mode only.
CR295X (retired)
CR300
CR3000 (retired)
CR310
CR350
CR500 (retired)
CR5000 (retired) The CR5000 supports the SDI-12 mode only.
CR510 (retired)
CR800 (retired)
CR850 (retired)
CR9000 (retired)
CR9000X (retired)

Mounting Equipment

Product Compatible Note
ENC10/12 If using the RS-232 port, the AVW206 must be mounted flat to fit in an ENC10/12.
ENC10/12R If using the RS-232 port, the AVW206 must be mounted flat to fit in an ENC10/12Rl
ENC12/14 If using the RS-232 port, the AVW206 must be mounted flat to fit in an ENC12/14.
ENC14/16
ENC16/18
ENC24/30
ENC24/30S

Additional Compatibility Information

Sensors

The AVW206 Vibrating Wire Spectrum Analyzer Module allows our data loggers to measure vibrating wire strain gages, pressure transducers, piezometers, tiltmeters, crackmeters, and load cells.

Communications

The AVW206's internal spread spectrum radio can transmit data to an RF401A, RF401, or RF430. The AVW206 does not have a transparent mode, and therefore its internal radio cannot communicate with an RF400 radio.

Enclosure Considerations

The AVW206 requires a desiccated, non-condensing environment. A Campbell Scientific enclosure is recommended when the analyzer module is in the field. The AVW206 has built-in keyhole flanges for mounting to an enclosure backplate.

Power Considerations

The AVW206 is typically powered by the data logger's power supply.

Operating System Considerations

Newer modules with 250 mW radios must use OS 5 or higher for their operating system.

Downloads

AVW200 OS v.06 (551 KB) 10-06-2016

Current AVW200 firmware. Use the Device Configuration Utility version 1.13 or greater to send firmware and to configure the AVW200.

View Update History

Casos de estudio

Louisiana: Monitoring Bridge Expansion
The four main spans of the Huey P. Long Bridge extend nearly 2,400 ft over......read more
Kentucky: Dam Repair
The Wolf Creek Dam near Jamestown, Kentucky, was constructed partially as a regular concrete hydroelectric......read more