Services Available | |
---|---|
Repair | Yes |
Calibration | No |
Free Support | Yes |
The SDM-SIO1 is an RS-232, RS-422, or RS-485 serial expansion module. Up to fifteen SDM-SIO1 modules may be connected to a single datalogger SDM interface. This module is commonly used to interface serial sensors to a datalogger. Please refer to the Compatibility information regarding which dataloggers the SDM-SIO1 may be used with.
Read MoreThe SDM-SIO1 is a serial expansion module that allows a data logger to communicate with serial devices that interface using true RS-232, RS-422, or RS-485 signals. Up to fifteen SDM-SIO1 modules may be connected to a single data logger SDM interface. Remote serial devices use industry standard hardware and protocols to connect to the data logger through the SDM-SIO1 interface. When operating in the RS-232 mode, the module also provides hardware handshaking. The SDM-SIO1 Module is implemented in such a way that it looks like a built-in serial port to the user when writing programs in CRBasic. This means that all the user needs to do is define the address of the SDM-SIO1, using a rotary switch on the side of the unit. The serial port can then be used as if it were built into the data logger.
Modes of Operation |
|
Data Rates | 300, 1200, 2400, 4800, 9600, 19200, 38400, 57600, or 115200 bps |
Data Format |
|
EMC Compliance | Complies with IEC 61326. |
Power Supply Connection | +12 V |
Operating Voltage |
|
Operating Temperature | -25° to +55°C |
Dimensions | 5.4 x 8.0 x 2.5 cm (2.2 x 3.1 x 1.0 in.) |
Current Drain |
|
Standby |
|
Active | 5 to 13 mA (depending on transmit mode and connections made) |
Buffer |
|
Storage Type | Both transmit and receive buffers are fill and discard. |
Transmit-Buffer Size | 767 bytes (buffer from data logger to sensor) |
Receive-Buffer Size | 2047 bytes (buffer from sensor to data logger) |
Please note: The following shows notable compatibility information. It is not a comprehensive list of all compatible products.
Product | Compatible | Note |
---|---|---|
CR1000 (retired) | ||
CR200X (retired) | ||
CR206X (retired) | ||
CR211X (retired) | ||
CR216X (retired) | ||
CR295X (retired) | ||
CR3000 (retired) | SDMs are connected to the ports labeled SDM-C1, SDM-C2, and SDM-C3. | |
CR5000 (retired) | The CR5000 operating system must be OS 6 or higher. SDMs are connected to the ports labeled SDM-C1, SDM-C2, and SDM-C3. |
|
CR6 | ||
CR800 (retired) | ||
CR850 (retired) | ||
CR9000X (retired) | The CR9000X operating system must be OS 6 or higher. |
The SDM-SIO1A does NOT support auto baud rate detection nor the use of the serial port for general PakBus communications.
The SDM-SIO1 requires a desiccated, non-condensing environment. The SDM-SIO1 has built-in keyhole flanges for mounting to the backplates of Campbell Scientific enclosures.
Current firmware for the SDM-SIO1.
Note: If your version of DevConfig does not support the download of *.hex files, you will need to type in the file name directly or display it by typing *.hex and selecting the file name from the filtered list.