The CSAT3BH is ideal for stations that are deployed in cold climates. The easy-to-use CSAT3BH sonic anemometer features smart heating that delivers just the right amount of heat to keep the instrument free of ice and snow, enabling continuous and reliable measurements in cold environments. The CSAT3BH is designed to prevent ice accumulation on the sensor, avoiding prolonged periods of data loss.
The CSAT3BH features variable power, only delivering power when needed—as opposed to the common method of providing two-way heating (on/off). Moreover, there are real-time data flags when the heaters are turned on, which is crucial to post-processing your data files.
The CSAT3BH is a heated version of the CSAT3B 3-D Sonic Anemometer with Integrated Electronics. The specifications of the CSAT3BH are the same as the CSAT3B with regard to wind measurements.
Read MoreThe CSAT3BH provides integrated two-zone smart heating:
The smart heating uses environmental conditions and a controller to apply variable heating to the sonic anemometer to keep the body and transducers free of ice and snow. The CSAT3BH is designed to prevent ice from forming on the arms and fingers of the system. The block has no heating in it. The CSAT3BH has a separate controller that is used to control the heating algorithm of the sensor. The controller requires a temperature/RH input. There is an ambient temperature and relative humidity sensor that is standard for use with the controller, or the data can be provided through a user-supplied temperature/RH sensor.
The CSAT3H heater controller is a polycarbonate enclosure sized 20.32 x 25.4 x 15.24 cm (8 x 10 x 6 in.). The enclosure uses connectors for incoming power, heaters, temperature sensors, temperature/RH, RS-485(2), and USB.
The heaters are controlled on two zones and require 150 W at full power. The controller controls the heaters by increasing or decreasing the voltage to get the appropriate wattage to keep ice from forming on the sensor.
Sensor | 3-dimensional sonic anemometer |
Measurement Description | Highest-quality wind speed and direction |
Operating Temperature Range | -40 to +50°C (equivalent to 305 to 368 m s-1 in speed of sound) |
Outputs | ux, uy, uz, Ts (ux, uy, uz are wind components referenced to the anemometer axes; Ts is sonic temperature in degrees Celsius.) |
Speed of Sound | Determined from three acoustic paths. (Corrected for crosswind effects.) |
Wind Direction Range | 2.5 to 357.5° in CSAT3B coordinate system (0 to 360° customized) |
Filter Bandwidths | 5, 10, 20, or 25 Hz |
Measurement Path Length | 10.0 cm (3.9 in.) vertical; 5.8 cm (2.3 in.) horizontal |
Transducer Angle from Horizontal | 60 degrees |
Transducer Diameter | 0.64 cm (0.25 in.) |
Transducer Mounting Arm Diameter | 0.84 cm (0.33 in.) |
Support Arm Diameter | 1.59 cm (0.63 in.) |
Anemometer Head Weight | 1.9 kg (4.2 lb) |
Anemometer Dimensions | 63.1 x 12.3 x 43.3 cm (24.8 x 4.9 x 17.0 in.) |
Power Requirements |
|
Anemometer Voltage Requirement | 9.5 to 32 Vdc |
Current Required for 10 Hz Measurement Rate |
|
Current Required for 100 Hz Measurement Rate |
|
Heaters | 6.2 A (@ 24 Vdc) |
Arms and Strut |
|
Transducer Fingers |
|
Total System Power |
|
Controller Current Required | 30 mA (heaters off [quiescent] @ 24 Vdc) |
Wind Accuracy |
|
-NOTE- |
Accuracy specifications assume the following:
|
Maximum Offset Error | < ±8.0 cm s-1 (ux, uy), < ±4.0 cm s-1 (uz) |
Maximum Gain Error |
|
Measurement Resolution |
|
ux, uy | 1 mm s-1 RMS |
uz | 0.5 mm s-1 RMS |
Ts | 0.002°C RMS (at 25°C) |
Wind Direction | < 0.058° (ux = uy ≤ 1 m s-1) |
Measurement Rates |
|
Data Logger Triggered | 1 to 100 Hz |
Unprompted Output (to PC) | 10, 20, 50, or 100 Hz |
Internal Self-Trigger Rate | 100 Hz |
Measurement Delay |
|
Data Logger Triggered (no filter) | 1 trigger period (1 scan interval) |
Unprompted Output (no filter) | 10 ms |
Filtered Output (data-logger-prompted or unprompted to PC) |
|
Internal Monitor Measurements |
|
Update Rate | 2 Hz |
Inclinometer Accuracy | ±1° |
Relative Humidity Accuracy |
|
Board Temperature Accuracy | ±2°C |
SDM |
|
-NOTE- | Used for data-logger-based data acquisition. |
Bit Period | 10 µs to 1 ms |
Cable Length |
|
Address Range | 1 to 14 |
Bus Clocks per Sample | ~200 |
CPI |
|
-NOTE- | Used for data-logger-based data acquisition. |
Baud Rate | 50 kbps to 1 Mbps |
Cable Length |
|
Address Range | 1 to 120 |
Bus Clocks per Sample | ~300 |
RS-485 |
|
-NOTE- | Used for anemometer configuration or PC-based data acquisition. |
Baud Rate | 9.6 kbps to 115.2 kbps |
Cable Length |
|
Bus Clocks per Sample | ~500 (ASCII formatted) |
USB |
|
-NOTE- | Used for anemometer configuration or PC-based data acquisition. |
Connection Speed | USB 2.0 full speed 12 Mbps |
Cable Length | 5 m (16.4 ft) maximum |
CR1000X datalogger programs for the CSAT3BH with SDM and CPI communications protocols.
Warning: This program is not intended for the CSAT3H Heater Controller Enclosure. Please contact Campbell Scientific for any questions regarding the CSAT3H Heater Controller program.
CR6 datalogger programs for the CSAT3BH with SDM and CPI communications protocols.
Warning: This program is not intended for the CSAT3H Heater Controller Enclosure. Please contact Campbell Scientific for any questions regarding the CSAT3H Heater Controller program.
The CSAT3H Heater Controller ships with this encrypted program. This program is for the unlikely event that the program needs to be re-installed or updated to a newer version. Please contact Campbell Scientific if you have questions about the program or would like the algorithm modified for a specific application.
Number of FAQs related to CSAT3BH: 3
Expand AllCollapse All
When the heaters are on, a flag is sent to the data logger to help the user determine if the heaters have an effect on the data.
The heaters can be controlled manually only through a programming change of the CR300 Datalogger used to control the heaters.