The 43347-L, manufactured by R. M. Young, is a highly accurate RTD that often provides delta temperature measurements for air quality applications. Typically, it is housed in the 43502 fan-aspirated radiation shield, which greatly reduces radiation errors.
Read MoreTo determine delta temperature, a 43347 probe mounted in a 43502 shield is attached to the mast of a UT20 or UT30 tower, while another 43347 probe mounted in a 43502 shield is attached to the tower at a 2-m height. The temperature difference of the two measurement heights is calculated and used to determine atmospheric stability as required by the EPA.
The 43347 may also be housed in a 41003-5 Naturally Aspirated Shield if fan-driven aspiration is not required. Additional hardware is required (see Ordering Info and Compatibility).
The standard 43347 probe has an RTD uncertainty of ±0.3°C. If increased accuracy is required, a three point calibration can be ordered that allows the RTD to have an uncertainty of only ±0.1°C.
Sensor Description | 1000 Ω Platinum RTD |
Measurement Description | Temperature |
Signal Type/Output | Analog voltage |
Operating Temperature Range | ±50°C |
Range | ±50°C |
Accuracy | ±0.3°C at 0°C; ±0.1°C with NIST calibration |
Temperature Coefficient | 0.00375 Ω/Ω °C |
Radiation Error / Ambient Temperature | < 0.2°C RMS at 1000 W/m2 intensity (when housed in the 43502 shield) |
Radiation Error / Delta T | < 0.05°C RMS with 43502 shields equally exposed (when housed in the 43502 shield) |
Stainless-Steel Sheath Diameter | 0.478 cm (0.188 in.) |
Stainless-Steel Sheath Length | 6.12 cm (2.41 in.) |
Probe Tip Length | 10.08 cm (3.97 in.) stainless-steel sheath and molded plastic |
Length | 17.8 cm (7 in.) |
Weight | 0.54 kg (1.2 lb) |
Please note: The following shows notable compatibility information. It is not a comprehensive list of all compatible products.
Product | Compatible | Note |
---|---|---|
CR1000 (retired) | ||
CR1000X | ||
CR300 | ||
CR3000 (retired) | ||
CR310 | ||
CR350 | ||
CR6 | ||
CR800 (retired) | ||
CR850 (retired) |
The 43347 is typically housed in a 43502 Aspirated Radiation Shield to provide delta-temperature measurements for air quality applications. Delta temperature measurements use two 43502s attached at different heights.
The 41003-5 naturally aspirated radiation shield can serve as an alternative to the 43502 if a fan-driven aspiration shield is not required. The 27251 split nut plug must be used.
Both the 43502 and 41003-5 can be attached to either a mast or crossarm.
The 43347 comes in two versions—the "IX" version and the "VX" version. The "IX" version connects to a current excitation channel; only the CR3000 and CR5000 are compatible with the -IX.
The "VX" version connects directly to voltage excitation channels. All compatible data loggers can use the VX version.