OBS-5+ Monitoring System with Pressure Sensor for High Suspended-Sediment Concentrations
Services Available
Repair No
Calibration No
Free Support No

Overview

The OBS-5+ monitors high sediment concentrations using an infrared laser and a proprietary dual photo-detection system (U.S. Patent No. 5,796,481). The probe transmits sediment concentration and depth to a PC via an RS-232 or RS-485 link. Data are also stored internally.

The OBS-5+ is ideal for monitoring dredging and site-remediation operations, determining dredge efficiency, providing data for sediment transport research, and supporting undersea mining and trenching.

(OBS® is a registered trademark of Campbell Scientific.)

Read More

Benefits and Features

  • Connects directly to a PC—no datalogger needed
  • Operates up to six months on three C-cell batteries
  • Monitors high sediment concentrations (up to 200g/l)
  • Records 200,000 scans of data in the OBS-5+ flash memory

Images

Detailed Description

The OBS-5+ has a Windows GUI that enables the user to generate and store sediment calibration tables, log data, program logging/sampling schemes, and graphically display data. Using the Windows GUI, an operator can calibrate the OBS-5+ with sediments, change electronics gain to optimize resolution, create as many as 15 unique sediment lookup tables, and store those tables in FLASH memory for future use. Users can complete the entire calibration process without spreadsheet calculations and curve fitting.

Advantage of Multiple Detectors

The OBS-5+ uses multiple detectors and an embedded controller, which extend the measurement range of the sensor by a factor of about ten. One limitation of our single-detector systems like the OBS-3+ is that they cannot measure suspended solids concentration (SSC) levels greater than about 10 g l-1 (mud) and 100 g l-1 (sand).

The OBS-5+ projects a beam of near infrared (NIR) laser light into a water sample next to two photodetectors. Suspended particles scatter light from the beam onto the detectors and a microcontroller determines SSC from their photocurrents. Because the detectors are unequally spaced from the laser, the particle concentrations corresponding to the peak response are also unequal and after being calibrated with sediment, an OBS-5+ can measure and uniquely resolve sediment SSC values greater than the peaks in response.

The OBS-5+ has been used extensively to monitor dredging and mining operations in the US, EU, China, Vietnam, and Indonesia.

Reference

John Downing. 1998. Suspended Particle Concentration Monitor. U.S. Patent Number 5,796,481.

(OBS® is a registered trademark of Campbell Scientific.)

Specifications

Connector MCBH-8-FS, wet-pluggable
Wetted Materials 316 stainless steel, Delrin, and 20% GF polycarbonate
Operating Temperature Range 0° to 40°C
Storage Temperature Range -20° to +70°C
Infrared Wavelength 780 nm
Scattering Angles 105° to 165° (clean water)
Drift over Time < 30 ppm per month
Drift over Temperature < 200 ppm per °C
Maximum Sampling Rate 25 Hz
Maximum Data Rate 2 Hz
Data Capacity 8 MB
Maximum Number of Data Lines 200,000
Battery Capacity 8 Ahr
Maximum Battery Life 3,000 h
External Supply Voltage 6 to 18 Vdc
External Supply Current 55 mA
PC Interfaces RS-232/115 kbps, RS-485/115 kbps
Diameter 6.0 cm (2.4 in.)
Length 38.0 cm (15 in.)
Weight 2.04 kg (4.5 lb)
Submerged Weight 1.02 kg (2.3 lb)

Accuracy

Sediment Concentration
  • 2% of reading (for mud)
  • 4% of reading (for sand)
Pressure 0.5% of full scale
Turbidity 1.5% of full scale

Compatibility